Additional guidance 7.4

7.4

If a loadbearing wall is any of the following, guidance in other sections may also apply.

a. A compartment wall (including a wall common to two buildings): Section 8.
b. Enclosing a place of special fire hazard: Section 8, paragraph 8.7.
c. Protecting a means of escape: Sections 2 to 5.
d. An external wall: Sections 12 and 13.
e. Enclosing a firefighting shaft: Section 17.

View this page on RegsUK