Introduction How to use this approved document

How to use this approved document

Each approved document contains:

• general guidance on the performance expected of materials and building work in order to comply with each of the requirements of the Building Regulations, and
• practical examples and solutions on how to achieve compliance for some of the more common building situations.

They may not provide appropriate guidance if the case is unusual in terms of its design, setting, use, scale or technology. Non-standard conditions may include any of the following:

• difficult ground conditions
• buildings with unusual occupancies or high levels of complexity
• very large or very tall buildings
• large timber buildings
• some buildings that incorporate modern construction methods.

Anyone using the approved documents should have sufficient knowledge and skills to understand the guidance and correctly apply it to the building work. This is important because simply following the guidance does not guarantee that your building work will comply with the legal requirements of the Building Regulations. Each approved document contains legal requirements (which you must follow) and guidance (which you may or may not choose to follow). The text in a box with a green background at the beginning of each section of an approved document is taken from the Building Regulations. This text sets out the legal requirements.

The explanation which follows the legal requirements is guidance (see Diagram i below). The guidance then explains one or more ways to demonstrate how building work can be shown to comply with the legal requirements in common circumstances. The terms in green lettering in an approved document are key terms, listed and explained in the appendix to that approved document. Guidance in the approved documents addresses most, but not all, situations that building owners will face. Situations may arise that are not covered. You or your advisers will need to carefully consider whether following the guidance will mean that the requirements of the Building Regulations will be met.

For further information about the use of technical guidance, see Chapter 7 in Volume 1 and Chapter F in Volume 2 of the Manual to the Building Regulations.

Diagram i The relationship between regulations and guidance in the approved documents

Diagram i The relationship between regulations and guidance in the approved documents. Wording on the drawing: B2; Requirement B2: Internal fire spread (linings); This section deals with the following requirement from Part B of Schedule 1 to the Building Regulations 2010.; Requirement; Requirement Limits on application; Internal fire spread (linings); B2. (1) To inhibit the spread of fire within the building,; the internal linings shall—; ➊; (a) adequately resist the spread of flame over; their surfaces; and; (b) have, if ignited, either a rate of heat release; or a rate of fire growth, which is reasonable in the circumstances.; (2) In this paragraph “internal linings” means the; materials or products used in lining any partition, wall, ceiling or other internal structure.; Intention; In the Secretary of State’s view, requirement B2 is met by achieving a restricted spread of flame over internal linings. The building fabric should make a limited contribution to fire growth, including a low rate of heat release.; It is particularly important in circulation spaces, where linings may offer the main means by which fire spreads and where rapid spread is most likely to prevent occupants from escaping.; ➋; Requirement B2 does not include guidance on the following.; a. Generation of smoke and fumes.; b. The upper surfaces of floors and stairs.; c. Furniture and fittings.; Key; ➊ ➋; The law: extract from the Building Regulations 2010.; Statutory guidance.
Diagram i The relationship between regulations and guidance in the approved documents

View this page on RegsUK