0.1
This approved document has been published in two volumes. Volume 1 deals solely with dwellings, including blocks of flats, while Volume 2 deals with all other types of building covered by the Building Regulations.
Arrangement of sections
0.2
Requirements B1–B5 of Schedule 1 to the Building Regulations are dealt with separately in one or more sections. Each requirement is shown at the start of the relevant sections.
0.3
The provisions in this document have the following aims:
Requirement B1: When there is a fire, ensure both:
Requirement B2: Inhibit the spread of fire over internal linings of buildings.
Requirement B3: The building must be built such that all of the following are achieved in the event of a fire:
Requirement B4: Restrict both:
Requirement B5: Ensure both:
Regulation 38: Provide fire safety information to building owners.
0.4
Guidance is given on each aspect separately, though many are closely interlinked. The document should be considered as a whole. The relationship between different requirements and their interdependency should be recognised. Particular attention should be given to the situation where one part of the guidance is not fully followed as this could have a negative effect on other provisions.
Appendices: Information common to more than one requirement of Part B
0.5
Guidance on matters that refer to more than one section of this document can be found in the following appendices.
Appendix A: Key terms
Appendix B: Performance of materials, products and structures
Appendix C: Fire doorsets
Appendix D: Methods of measurement
Appendix E: Sprinklers
Appendix F: Standards referred to
Appendix G: Documents referred to
Management of premises
0.6
The Building Regulations do not impose any requirements on the management of a building, but do assume that it will be properly managed. This includes, for example, keeping protected escape routes virtually ‘fire sterile’.
Appropriate fire safety design considers the way in which a building will be managed. Any reliance on an unrealistic or unsustainable management regime cannot be considered to have met the requirements of the regulations.
Once the building is in use, the management regime should be maintained and a suitable risk assessment undertaken for any variation in that regime. Failure to take proper management responsibility may result in the prosecution of an employer, building owner or occupier under legislation such as the Regulatory Reform (Fire Safety) Order 2005.
Property protection
0.7
The Building Regulations are intended to ensure a reasonable standard of life safety in a fire. The protection of property, including the building itself, often requires additional measures. Insurers usually set higher standards before accepting the insurance risk.
Many insurers use the RISCAuthority Design Guide for the Fire Protection of Buildings by the Fire Protection Association (FPA) as a basis for providing guidance to the building designer on what they require.
Further information on the protection of property can be obtained from the FPA website: www.thefpa.co.uk.
Inclusive design
0.8
The fire safety aspects of the Building Regulations aim to achieve reasonable standards of health and safety for people in and around buildings.
People, regardless of ability, age or gender, should be able to access buildings and use their facilities. The fire safety measures incorporated into a building should take account of the needs of everyone who may access the building, both as visitors and as people who live or work in it. It is not appropriate, except in exceptional circumstances, to assume that certain groups of people will be excluded from a building because of its use.
The provisions in this approved document are considered to be of a reasonable standard for most buildings. However, some people’s specific needs might not be addressed. In some situations, additional measures may be needed to accommodate these needs. This should be done on a case-by-case basis.
Alternative approaches
0.9
The fire safety requirements of the Building Regulations will probably be satisfied by following the relevant guidance in this approved document. However, approved documents provide guidance for some common building situations and there may be alternative methods of complying with the Building Regulations’ requirements.
If alternative methods are adopted, the overall level of safety should not be lower than the approved document provides. It is the responsibility of those undertaking the work to demonstrate compliance.
If other standards or guidance documents are adopted, the relevant fire safety recommendations in those publications should be followed in their entirety. However, in some circumstances it may be necessary to use one publication to supplement another. Care must be taken when using supplementary guidance to ensure that an integrated approach is used in any one building.
Guidance documents intended specifically for assessing fire safety in existing buildings often include less onerous provisions than those for new buildings and are therefore unlikely to be appropriate for building work that is controlled by the Building Regulations.
Buildings for industrial and commercial activities that present a special fire hazard, e.g. those that sell fuels, may require additional fire precautions to those in this approved document.
Health care premises
0.10
Health care premises and the patients who use them are diverse. Patients using the premises require different types of care to suit their specific needs. The choice of fire safety strategy depends on both of the following.
The Department of Health (DoH) guidance documents on fire precautions in health care buildings, Firecode, take account of the particular characteristics of these buildings and should be followed.
Firecode contains managerial and other fire safety provisions that are outside the scope of the Building Regulations.
Unsupervised group homes
0.11
An unsupervised group home for not more than six mental health service users should be regarded as having a purpose group of either of the following.
Shopping complexes
0.12
Although the guidance in this document may be readily applied to individual shops, shopping complexes present different escape problems. The design of units within a shopping complex should be compatible with the fire strategy for the complex as a whole. A suitable approach is given in Annex E of BS 9999.
Assembly buildings
0.13
Assembly buildings where a large number of people are present require additional considerations for means of escape; for example, fixed seating may limit the ability of people to escape.
Guidance on fixed seating and other aspects of means of escape in assembly buildings is given in Annex D of BS 9999.
For buildings to which the Safety of Sports Grounds Act 1975 applies, the Sports Grounds Safety Authority’s Guide to Safety at Sports Grounds should also be followed.
Schools
0.14
The design of fire safety in schools is covered by Building Bulletin 100, which should be used. Building Bulletin 100 contains fire safety provisions that are outside the scope of the Building Regulations.
Prisons provided under section 33 of the Prisons Act 1952
0.15
Prisons are exempted from the functional requirements of Parts B1 to B5 of the Building Regulations under section 33 of the Prisons Act 1952. It is usual that prisons should comply with the fire safety requirements of the Building Regulations, except where the requirements are incompatible with safe custody, good order or security.
HM Prison and Probation Service (HMPPS) provides guidance documents on fire precautions in prisons, which take account of the public safety need to secure doors and exits while maintaining life safety objectives.
The HMPPS Custodial Premises Fire Safety Design Guide (FSDG) is the design standard for fire safety in prisons, providing structured guidance for those involved in the planning, designing or approval of new or altered buildings.
Further guidance documents on fire safety in prisons are provided by HMPPS. These documents may also be used for other places of lawful detention.
Buildings containing one or more atria
0.16
A building with an atrium that passes through compartment floors may need special fire safety measures. Guidance is given in Annexes B and C of BS 9999.
Buildings of special architectural or historic interest
0.17
Where Part B applies to existing buildings, particularly buildings of special architectural or historic interest for which the guidance in this document might prove too restrictive, some variation of the provisions in this document may be appropriate. In such cases, it is appropriate to assess the hazard and risk in the particular case and consider a range of fire safety features in that context.
Fire safety engineering
0.18
Fire safety engineering might provide an alternative approach to fire safety. Fire safety engineering may be the only practical way to achieve a satisfactory standard of fire safety in some complex buildings and in buildings that contain different uses.
Fire safety engineering may also be suitable for solving a specific problem with a design that otherwise follows the provisions in this document.
0.19
BS 7974 and supporting published documents (PDs) provide a framework for and guidance on the application of fire safety engineering principles to the design of buildings.
Purpose groups
0.20
Building uses are classified within different purpose groups, which represent different levels of hazard (see Table 0.1). A purpose group can apply to a whole building or to a compartment within the building, and should relate to the main use of the building or compartment.
0.21
Where a building or compartment has more than one use, it is appropriate to assign each different use to its own purpose group in the following situations.
0.22
Where there are multiple main uses that are not ancillary to one another (for example, shops with independent offices above), each use should be assigned to a purpose group in its own right. Where there is doubt as to which purpose group is appropriate, the more onerous guidance should be applied.
Table 0.1 Classification of purpose groups
| Volume 1 purpose groups | ||
|---|---|---|
| Title | Group | Purpose for which the building or compartment of a building is intended to be used |
| Residential (dwellings) | 1(a)(1) | Flat. |
| 1(b)(2) | Dwellinghouse that contains a habitable storey with a floor level a minimum of 4.5m above ground level up to a maximum of 18m.(3) | |
| 1(c)(2)(4) | Dwellinghouse that does not contain a habitable storey with a floor level a minimum of 4.5m above ground level. | |
| Volume 2 purpose groups | ||
| Residential (institutional) | 2(a) | Hospital, home, school or other similar establishment, where people sleep on the premises. The building may be either of the following: • Living accommodation for, or accommodation for the treatment, care or maintenance of, either: - disabled people with a range of impairments including physical, sensory and cognitive impairments, or mental health conditions - people under the age of 5 years. • A place of lawful detention. |
| Residential (other) | 2(b) | Hotel, boarding house, residential college, hall of residence, hostel or any other residential purpose not described above. |
| Office | 3 | Offices or premises used for any of the following and their control: • administration • clerical work (including writing, bookkeeping, sorting papers, filing, typing, duplicating, machine calculating, drawing and the editorial preparation of matter for publication, police and fire and rescue service work) • handling money (including banking and building society work) • communications (including postal, telegraph and radio communications) • radio, television, film, audio or video recording • performance (premises not open to the public). |
| Shop and commercial | 4 | Shops or premises used for either of the following. • A retail trade or business (including selling food or drink to the public for immediate consumption, retail by auction, self-selection and over-the-counter wholesale trading, the business of lending books or periodicals for gain, the business of a barber or hairdresser, and the rental of storage space to the public). • Premises to which the public are invited either: – to deliver or collect goods in connection with their hire, repair or other treatment – (except in the case of repair of motor vehicles) where the public themselves may carry out such repairs or other treatments. |
| Assembly and recreation | 5 | Place of assembly, entertainment or recreation, including any of the following: • bingo halls, broadcasting, recording and film studios open to the public, casinos, dance halls • entertainment, conference, exhibition and leisure centres • funfairs and amusement arcades • museums and art galleries, non-residential clubs, theatres, cinemas, concert halls • educational establishments, dancing schools, gymnasia, swimming pool buildings, riding schools, skating rinks, sports pavilions, sports stadia • law courts • churches and other buildings of worship, crematoria • libraries open to the public, non-residential day centres, clinics, health centres and surgeries • passenger stations and termini for air, rail, road or sea travel • public toilets • zoos and menageries. |
| Industrial | 6 | Factories and other premises used for any of the following: • manufacturing, altering, repairing, cleaning, washing, breaking up, adapting or processing any article • generating power • slaughtering livestock. |
| Storage and other nonresidential(4) | 7(a) | Either of the following: • place (other than described under 7(b)) for the storage or deposit of goods or materials • any building not within purpose groups 1 to 6. |
| 7(b) | Car parks designed to admit and accommodate only cars, motorcycles and passenger or light goods vehicles that weigh a maximum of 2500kg gross. | |
NOTES:
This table only applies to Part B.
See Approved Document B Volume 1 for guidance on dwellings (purpose group 1).
Mixed use buildings
0.23
This approved document includes reference to selected guidance for dwellings. For the design of mixed use buildings which include dwellings, Approved Document B Volume 1 should be consulted in addition to the guidance contained in this approved document.
0.24
Where a complex mix of uses exists, the effect that one use may have on another in terms of risk should be considered. It could be necessary to use guidance from both volumes, apply other guidance (such as from HTM 05-02 or Building Bulletin 100), and/or apply special measures to reduce the risk.