External walls (resistance to surface condensation and mould growth) 5.36

5.36

An external wall will meet the requirement if:

a. it is designed and constructed so that the thermal transmittance (U-value) does not exceed 0.7W/m2K at any point; and
b. the junctions between elements and details of openings, such as doors and windows, are designed to Accredited Construction Details99, or follow the guidance of BRE IP17/01132.

99 Accredited Construction Details which can be downloaded from www.planningportal.gov.uk/buildingregulations/approveddocuments/partl/bcassociateddocuments9/acd.

126 BRE GBG 47 Level external thresholds: reducing moisture penetration and thermal bridging, 2001.

127 Accessible thresholds in new buildings: guidance for house builders and designers, TSO, 1999.

128 The drainage channel and adjacent paving and threshold are usually made up from precast concrete or other pre-formed components.

129 BS 5250:2002 Code of practice for the control of condensation in buildings.

130 BS EN ISO 13788:2002 Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods.

132 BRE Information Paper IP17/01 Assessing the effects of thermal bridging at junctions and around openings, 2001.