Section 5: Walls External walls (resistance to damage from interstitial condensation)

External walls (resistance to damage from interstitial condensation)

5.34

An external wall will meet the requirement if it is designed and constructed in accordance with Clause 8.3 of BS 5250:2002129, and BS EN ISO 13788:2002130.

5.35

Because of the high internal temperatures and humidities, there is a particular risk of interstitial condensation in the walls of swimming pools and other buildings in which high levels of moisture are generated; specialist advice should be sought when these are being designed.

View this page on RegsUK