Section 4: Floors Floors (resistance to surface condensation and mould growth)

Floors (resistance to surface condensation and mould growth)

4.22

A floor will meet the requirement if:

a. a ground floor is designed and constructed so that the thermal transmittance (U-value) does not exceed 0.7W/m2K at any point; and
b. in the case of all floors, the junctions between elements are designed to Accredited Construction Details99, or follow the guidance of BRE IP17/01100.

96 BS 5250:2002 Code of practice for the control of condensation in buildings.

97 BS EN ISO 13788:2002 Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods.

98 BRE Report BR 262 Thermal insulation: avoiding risks, 2002.

99 Accredited Construction Details which can be downloaded from www.planningportal.gov.uk/buildingregulations/approveddocuments/partl/bcassociateddocuments9/acd.

100 BRE Information Paper IP17/01 Assessing the effects of thermal bridging at junctions and around openings, 2001.