Section 1: Simplified method Categorising residential buildings (simplified method)
Categorising residential buildings (simplified method)
1.2
For the simplified method, the strategy to reduce overheating risk should be selected according to the location of the new residential building and whether it has cross-ventilation, following paragraphs 1.3 to 1.5.
1.3
For the purposes of following the simplified method, the building’s overheating risk category is determined by its location in one of the following areas.
NOTE: Appendix C also provides guidance for some parts of central Manchester.
1.4
For the purposes of following the simplified method, it should be identified whether the dwellinghouse or each residential unit, shared communal room and common space is able to have cross-ventilation, i.e. it has openings on opposite façades.
NOTE: Having openings on façades that are not opposite does not meet the approved document definition of cross-ventilation, e.g. in a corner flat.
NOTE: A multi-occupancy residential building should not be categorised as having or not having cross-ventilation. Each residential unit, shared communal room and common space should be categorised separately.
1.5
The building’s overheating risk category based on location and whether it is cross-ventilated should be used to select the relevant guidance for both of the following purposes.