Locks, hinges and letter plates B.6
B.6
The main doors for entering a dwelling (usually the front doorset) should be fitted with a multipoint locking system that meets the requirements of:
• PAS 3621 (key locking on both sides), or
• PAS 8621 (non-key locking on the internal face), or
• PAS 10621 (non-key locking on the internal face, but with an external locking override facility).
If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with a surface-mounted rim lock that conforms to the same standard:
• BS 3621 (key locking both sides), or
• BS 8621 (non-key locking on the internal face), or
• BS 10621 (non-key locking on the internal face, but with an external locking override facility).
Between the locking points for the mortice lock and surface-mounted rim lock, the distance should be 400–600mm.