Appendix B: Bespoke timber secure doorsets Locks, hinges and letter plates

Locks, hinges and letter plates

B.6

The main doors for entering a dwelling (usually the front doorset) should be fitted with a multipoint locking system that meets the requirements of:

• PAS 3621 (key locking on both sides), or
• PAS 8621 (non-key locking on the internal face), or
• PAS 10621 (non-key locking on the internal face, but with an external locking override facility).

If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with a surface-mounted rim lock that conforms to the same standard:

• BS 3621 (key locking both sides), or
• BS 8621 (non-key locking on the internal face), or
• BS 10621 (non-key locking on the internal face, but with an external locking override facility).

Between the locking points for the mortice lock and surface-mounted rim lock, the distance should be 400–600mm.

B.7

The non-primary doors for entering a dwelling (for example, back door or garage interconnecting doors) should be fitted with a multipoint locking system that meets the requirements of:

• PAS 3621 (key locking on both sides), or
• PAS 8621 (non-key locking on the internal face), or
• PAS 10621 (non-key locking on the internal face, but with an external locking override facility).

If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with two morticed bolts.

• BS 3621 (key locking both sides), or
• BS 8621 (non-key locking on the internal face), or
• BS 10621 (non-key locking on the internal door face, but with an external locking override facility).

The morticed bolts should have a minimum projection of 20mm, should be at least 100mm from the top and bottom corners of the door, and should avoid any door construction joints.

B.8

Hinges accessible from outside should incorporate hinge bolts.

B.9

Letter plates, where provided, should:

a. have a maximum aperture of 260mm x 40mm, and
b. incorporate a flap or other features designed to hinder anyone attempting to remove keys with sticks and/or insert their hand.

NOTE: Letter plates meeting the requirements of the Door and Hardware Federation’s (DHF’s) technical specification TS 008:2012 have been shown to protect against the attacks mentioned above.