Appendix B: Bespoke timber secure doorsets Locks, hinges and letter plates
Locks, hinges and letter plates
B.6
The main doors for entering a dwelling (usually the front doorset) should be fitted with a multipoint locking system that meets the requirements of:
If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with a surface-mounted rim lock that conforms to the same standard:
Between the locking points for the mortice lock and surface-mounted rim lock, the distance should be 400–600mm.
B.7
The non-primary doors for entering a dwelling (for example, back door or garage interconnecting doors) should be fitted with a multipoint locking system that meets the requirements of:
If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with two morticed bolts.
The morticed bolts should have a minimum projection of 20mm, should be at least 100mm from the top and bottom corners of the door, and should avoid any door construction joints.
B.8
Hinges accessible from outside should incorporate hinge bolts.
B.9
Letter plates, where provided, should:
NOTE: Letter plates meeting the requirements of the Door and Hardware Federation’s (DHF’s) technical specification TS 008:2012 have been shown to protect against the attacks mentioned above.