Locks, hinges and letter plates B.7
B.7
The non-primary doors for entering a dwelling (for example, back door or garage interconnecting doors) should be fitted with a multipoint locking system that meets the requirements of:
• PAS 3621 (key locking on both sides), or
• PAS 8621 (non-key locking on the internal face), or
• PAS 10621 (non-key locking on the internal face, but with an external locking override facility).
If it is not practical or desirable to install a multipoint locking system, a mortice lock that conforms with one of the following standards can be fitted instead, with two morticed bolts.
• BS 3621 (key locking both sides), or
• BS 8621 (non-key locking on the internal face), or
• BS 10621 (non-key locking on the internal door face, but with an external locking override facility).
The morticed bolts should have a minimum projection of 20mm, should be at least 100mm from the top and bottom corners of the door, and should avoid any door construction joints.