Appendix D: Methods of measurement Building dimensions

Building dimensions

Diagram D2 Cubic capacity

Diagram D2 Cubic capacity. Wording on the drawing: In every case measure the volume contained by all of the following.; a. Under surface of roof. Internal wall Internal wall b. Upper surface of or partition or partition lowest floor. Enclosing wall Enclosing wall Compartment floor c. Inner surface of enclosing walls. Compartment wall When there is not an outer enclosing wall, measure to the; outermost edge of the floor slab. a. Cubic capacity of a building b. Cubic capacity of compartments; or separated part of a building The measured volume should include internal walls and partitions.
Diagram D2 Cubic capacity

Diagram D3 Area

Diagram D3 Area. Wording on the drawing: a. Surface area: roofs and rooflights; In each case measure the visible area; Measure from outermost point of roof at eaves or verge; Lowest point of roof slope; If a hipped roof, asure to outermost t of roof at base area; Roof sheeting; me poin; at eaves; If a lean-to roof, measure from the face of wall to the outermost point of roof; Outermost; Highest point; point of roof; Rooflight; of roof slope; Section Elevation Section; Section; i. Flat or monopitch roof ii. Double pitch roof iii. Rooflight; b. Floor area: c. Floor area: Room, garage, conservatory or outbuilding, Storey, part or compartment, measure to inner surface of enclosing walls measure to inner surface of enclosing walls and include internal walls and partitions; When there is not an outer enclosing wall, measure to the outermost edge of the floor slab
Diagram D3 Area

Diagram D4 Height of building

Diagram D4 Height of building. Wording on the drawing: Highest point; Highest point; Highest point of parapet (including coping); of roof slope; of roof slope; Equal; Mean roof level; Equal; Mean roof level; Lowest point of roof slope; Height of building; a Top level of gutter; b; Highest level; of ground adjacent to outside walls; Mean ground level; Mean ground level; Use height a or b, whichever is greater; Lowest level; a. Double pitch roof; b. Mansard type roof; of ground adjacent to outside walls; Highest point; of roof slope; Mean roof level; Equal; Lowest point of roof slope; Height of building; Highest level; of ground adjacent to outside walls; Mean ground level; Lowest level; c. Flat or monopitch roof; of ground adjacent to outside walls
Diagram D4 Height of building

Diagram D5 Number of storeys

Diagram D5 Number of storeys. Wording on the drawing: Building three storeys; Second; floor; To count the number of storeys in a building, or in a separated part of a building, count only at the position which gives the greatest number and exclude any basement storeys.; First floor; Ground; floor; Basement; Separated part three storeys; Separated part two storeys Second; floor Compartment; NOTES:; wall First floor; 1. In assembly buildings (purpose group 5), a gallery is included as a storey, but not if it is a loading gallery, fly gallery, stage grid, lighting bridge, or any gallery provided for similar purposes, or for maintenance and repair.; Ground; floor; 2. In other purpose group buildings, galleries are not counted as a storey.; Basement; 3. For the definition of basement, see Appendix A.
Diagram D5 Number of storeys

Diagram D6 Height of top storey in building

Diagram D6 Height of top storey in building. Wording on the drawing: Plant; Roof; Height of top storey excludes roof-top plant areas and any top storeys consisting exclusively of plant rooms; Height of top storey measured from upper floor; surface of top floor to ground; level on lowest side of building
Diagram D6 Height of top storey in building