Appendix D: Methods of measurement Width

Width

D4

Width is measured according to the following.

a. For a door (or doorway), the clear width when the door is open (Diagram D1).
b. For an escape route, either of the following.
i. When the route is defined by walls: the width at 1500mm above finished floor level.
ii. Elsewhere: the minimum width of passage available between any fixed obstructions.
c. For a stair, the clear width between the walls or balustrades. On escape routes and stairs, handrails and strings intruding into the width by a maximum of 100mm on each side may be ignored. Rails used for guiding a stair-lift may be ignored, but it should be possible to park the lift’s chair or carriage in a position that does not obstruct the stair or landing.

Diagram D1 Measurement of door width

Diagram D1 Measurement of door width. Wording on the drawing: E°ective clear E°ective clear width (door stop width (door stop to to projecting door leaf) ironmongery)
Diagram D1 Measurement of door width