Cavity insulation 5.16

5.16

If the map given in Diagram 12 is used, determine the national exposure and, where appropriate, apply the following modifiers:

i. where local conditions accentuate wind effects, such as open hillsides or valleys where the wind is funnelled onto the wall, add one to this exposure zone value;
ii. where walls do not face into the prevailing wind, subtract one from this exposure zone value.

(The national exposure zone value can be more accurately calculated from the larger scale maps and correction factors given in BS 8104:1992112.)

112 BS 8104:1992 Code of practice for assessing exposure of walls to wind-driven rain.

Determine the recommended constructions from the modified exposure zone values given in Table 4. Further guidance as to the use of this table is given in BRE Report 262113.