Methane and other gases from the ground Remedial measures
Remedial measures
2.36
If the risks posed by the gas are unacceptable then these need to be managed through appropriate building remedial measures. Site-wide gas control measures may be required if the risks on any land associated with the building are deemed unacceptable. Such control measures include removal of the gas generating material or covering together with gas extraction systems. Further guidance is contained in CIRIA Report 14972. Generally speaking, expert advice should be sought in these circumstances.
2.37
Gas control measures for dwellings consist of a gas resistant barrier across the whole footprint (i.e. walls and floor) above an extraction (or ventilation) layer from which gases can be dispersed and vented to the atmosphere. They are normally passive, i.e. gas flow is driven by stack (temperature difference) and wind effects. Consideration should be given to the design and layout of buildings to maximise the driving forces of natural ventilation. Further guidance on this and detailed practical guidance on the construction of protective measures for housing is given in the BRE/Environment Agency report BR 41473. (In order to accommodate gas resistant membrane, for example as shown in BR414, the position and type of insulation may have to be adjusted). The DETR/Arup Environmental report74 compares the performance of a range of commonly used gas control measures and can be used as a guide to the design of such measures.
43 CLR 11. Model Procedures for the Management of Land Contamination. Defra/Environment Agency, 2004. www.environment-agency.gov.uk.
62 Institute of Petroleum TP 95 Guidelines for investigation and remediation of petroleum retail sites, 1998.
63 BGS Technical Report WP/95/1 Methane, carbon dioxide and oil seeps from natural sources and mining areas: characteristics, extent and relevance to planning and development in Great Britain, 1995.
64 Methane and other gases from disused coal mines: the planning response, DoE, 1996.
65 CIRIA Report 130 Methane: its occurrence and hazards in construction, 1993.
66 CIRIA Report 131 The measurement of methane and other gases from the ground, 1993.
67 CIRIA Report 150 Methane investigation strategies, 1995.
68 CIRIA Report 151 Interpreting measurements of gas in the ground, 1995.
69 CIRIA Report 152 Risk assessment for methane and other gases from the ground, 1995.
70 Environment Agency GasSIM – Landfill gas assessment tool.
72 CIRIA Report 149 Protecting development from methane, 1995.
2.38
Gas control measures for non-domestic buildings use the same principles as those used for housing, and the DETR/Arup Environmental report can also be used as a guide to design. Expert advice should be sought as the floor area of such buildings can be large and it is important to ensure that gas is adequately dispersed from beneath the floor. The use of mechanical (as opposed to passive) systems and monitoring and alarm systems may be necessary. There is a need for continued maintenance and calibration of these systems, so they are more appropriate with non-domestic buildings (as opposed to dwellings) since there is usually scope for this. Again, expert advice should be sought. Special sub-floor ventilation systems are carefully designed to ensure adequate performance and should not be modified unless subjected to a specialist review of the design. Such ventilation systems, particularly those using powered ventilation, are unlikely to be appropriate for owner occupied properties as there is a risk of interference by users.