Roofs (resistance to moisture from the outside) Technical solution
Technical solution
6.6
Roofing systems may be:
a. impervious including metal, plastic and bituminous products; or
b. weather resisting including natural stone or slate, cement based products, fired clay and wood; or
c. moisture resisting including bituminous and plastic products lapped at the joints, if used as a sheet material, and permeable to water vapour unless there is a ventilated space directly behind the material; or
d. jointless materials and sealed joints, which would allow for structural and thermal movement.
6.7
Dry joints between roofing sheets should be designed so that precipitation will not pass through them, or the system should be designed so that precipitation which enters the joints will be drained away without penetrating beyond the back of the roofing system. Note: Whether dry joints are suitable will depend on the design of the joint or the design of the roofing system and the severity of the exposure to wind and rain.
6.8
Each sheet, tile and section of roof should be fixed in an appropriate manner. Guidance as to appropriate fixing methods is given in BS 8000-6:1990134.