Cavity insulation Table 4 Maximum recommended exposure zones for insulated masonry walls
Table 4 Maximum recommended exposure zones for insulated masonry walls
| Wall construction | Maximum recommended exposure zone for each construction | |||||||
|---|---|---|---|---|---|---|---|---|
| Insulation method | Min. width of filled or clear cavity (mm) | Impervious cladding | Rendered finish | Facing masonry | ||||
| Full height of wall | Above facing masonry | Full height of wall | Above facing masonry | Tooled flush joints | Recessed mortar joints | Flush sills and copings | ||
| Built-in full fill | 50 | 4 | 3 | 3 | 3 | 2 | 1 | 1 |
| 75 | 4 | 3 | 4 | 3 | 3 | 1 | 1 | |
| 100 | 4 | 4 | 4 | 3 | 3 | 1 | 2 | |
| 125 | 4 | 4 | 4 | 3 | 3 | 1 | 2 | |
| 150 | 4 | 4 | 4 | 4 | 4 | 1 | 2 | |
| Injected fill not UF foam | 50 | 4 | 2 | 3 | 2 | 2 | 1 | 1 |
| 75 | 4 | 3 | 4 | 3 | 3 | 1 | 1 | |
| 100 | 4 | 3 | 4 | 3 | 3 | 1 | 1 | |
| 125 | 4 | 4 | 4 | 3 | 3 | 1 | 2 | |
| 150 | 4 | 4 | 4 | 4 | 4 | 1 | 2 | |
| Injected fill UF foam | 50 | 4 | 2 | 3 | 2 | 1 | 1 | 1 |
| 75 | 4 | 2 | 3 | 2 | 2 | 1 | 1 | |
| 100 | 4 | 2 | 3 | 2 | 2 | 1 | 1 | |
| Partial fill | ||||||||
| Residual 50mm cavity | 50 | 4 | 4 | 4 | 4 | 3 | 1 | 1 |
| Residual 75mm cavity | 75 | 4 | 4 | 4 | 4 | 4 | 1 | 1 |
| Residual 100mm cavity | 100 | 4 | 4 | 4 | 4 | 4 | 2 | 1 |
| Internal insulation | ||||||||
| Clear cavity 50mm | 50 | 4 | 3 | 4 | 3 | 3 | 1 | 1 |
| Clear cavity 100mm | 100 | 4 | 4 | 4 | 4 | 4 | 2 | 2 |
| Fully filled cavity 50mm | 50 | 4 | 3 | 3 | 3 | 2 | 1 | 1 |
| Fully filled cavity 100mm | 100 | 4 | 4 | 4 | 3 | 3 | 1 | 2 |