Section 2: Dynamic thermal modelling Acceptable strategies for reducing overheating risk

Acceptable strategies for reducing overheating risk

Limiting solar gains

2.7

Solar gains in summer should be limited by any of the following means.

a. Fixed shading devices, comprising any of the following.
i. Shutters.
ii. External blinds.
iii. Overhangs.
iv. Awnings.
b. Glazing design, involving any of the following solutions.
i. Size.
ii. Orientation.
iii. g-value.
iv. Depth of the window reveal.
c. Building design – for example, the placement of balconies.
d. Shading provided by adjacent permanent buildings, structures or landscaping.

2.8

Although internal blinds and curtains provide some reduction in solar gains, they should not be taken into account when considering whether requirement O1 has been met.

2.9

Foliage, such as tree cover, can provide some reduction in solar gains. However, it should not be taken into account when considering whether requirement O1 has been met.

NOTE: Examples of solar shading and their effectiveness are provided in the Building Research Establishment’s BR 364 Solar Shading of Buildings.

Removing excess heat

2.10

Excess heat should be removed from the residential building by any of the following means.

a. Opening windows (the effectiveness of this method is improved by cross-ventilation).
b. Ventilation louvres in external walls.
c. A mechanical ventilation system.
d. A mechanical cooling system

2.11

The building should be constructed to meet requirement O1 using passive means as far as reasonably practicable. It should be demonstrated to the building control body that all practicable passive means of limiting unwanted solar gains and removing excess heat have been used first before adopting mechanical cooling. Any mechanical cooling (air-conditioning) is expected to be used only where requirement O1 cannot be met using openings.

NOTE: Any method to reduce overheating risk in residential buildings must comply with all other parts of the Building Regulations. Particular attention should be paid to the requirements of Part F and the guidance in Approved Document F, Volume 1: Dwellings on noise and maintenance.

NOTE: A system for purge ventilation should be provided in each habitable room to demonstrate compliance with Part F of the Building Regulations. The guidance in Section 1 of Approved Document F, Volume 1: Dwellings should be followed for the minimum standards for purge ventilation. A larger amount of purge ventilation may be required than that in Approved Document F, Volume 1: Dwellings in order to satisfy requirement O1 on providing an adequate means to remove excess heat from the indoor environment.

View this page on RegsUK