Removing excess heat Table 1.4 Minimum free areas for buildings or parts of buildings without cross-ventilation
Table 1.4 Minimum free areas for buildings or parts of buildings without cross-ventilation
| High risk location | Moderate risk location | |
|---|---|---|
| Total minimum free area(1) | The greater of the following: a. 10% of the floor area(2) b. 95% of the glazing area(3) | The greater of the following: a. 12% of the floor area(2) b. 80% of the glazing area(3) |
| Bedroom minimum free area | 13% of the floor area of the room(4) | 4% of the floor area of the room(4) |
NOTES:
1. The total minimum free area is the free area for the whole dwellinghouse, residential unit, shared communal room or common space, including any bedrooms.
2. ‘Floor area’ is a key term. See Appendix A.
3. ‘Glazing area’ is a key term. See Appendix A.
4. ‘Floor area of the room’ is a key term. See Appendix A.