Removing excess heat Table 1.4 Minimum free areas for buildings or parts of buildings without cross-ventilation

Table 1.4 Minimum free areas for buildings or parts of buildings without cross-ventilation

High risk locationModerate risk location
Total minimum free area(1)The greater of the following: a. 10% of the floor area(2) b. 95% of the glazing area(3)The greater of the following: a. 12% of the floor area(2) b. 80% of the glazing area(3)
Bedroom minimum free area13% of the floor area of the room(4)4% of the floor area of the room(4)

NOTES:

1. The total minimum free area is the free area for the whole dwellinghouse, residential unit, shared communal room or common space, including any bedrooms.
2. ‘Floor area’ is a key term. See Appendix A.
3. ‘Glazing area’ is a key term. See Appendix A.
4. ‘Floor area of the room’ is a key term. See Appendix A.

View this page on RegsUK