Thatch and wood shingles Diagram 14.1 Limitations on spacing and size of plastic rooflights that have a class D-s3, d2 or TP(b) lower surface

Diagram 14.1 Limitations on spacing and size of plastic rooflights that have a class D-s3, d2 or TP(b) lower surface

Diagram 14.1 Limitations on spacing and size of plastic rooflights that have a class D-s3, d2 or TP(b) lower surface. Wording on the drawing: See paras 14.5 and 14.6; Rooflight* max. area 5m2; * Or group of rooflights amounting to no more than 5m2 † Class D-s3, d2 rooflights to rooms in industrial and other; non-residential purpose groups may be spaced 1800mm apart provided the rooflights are evenly distributed and do not exceed 20% of the area of the room; 3m† minimum between any two rooflights in any direction; NOTES:; 1. There are restrictions on the use of plastic rooflights in the guidance to requirement B2 in Section 6.; Rooflight* max. area 5m2; 2. Surrounding roof covering to be class B-s3, d2 for at least 3m distance.; 3. Where Diagram 8.2a or 8.2b applies, rooflights should be at least 1500mm from the compartment wall.