Method 1

13.18

This method applies to small buildings intended to be used for ‘residential (other)’ purposes.

13.19

The building should not exceed three storeys in height (excluding basements) or 24m in length. Each side of the building should meet the limits stated in Diagram 13.7. Any small unprotected areas falling within the limits shown in Diagram 13.5 can be ignored.

Diagram 13.7 Permitted unprotected areas in small residential buildings

Diagram 13.7 Permitted unprotected areas in small residential buildings. Wording on the drawing: See para 13.19; 24m max.; Minimum distance (a) Maximum total area of between side of building unprotected areas (m2) and relevant boundary (m); 1 5.6 2 12 3 18 4 24 5 30 6 No limit; a; Relevant boundary
Diagram 13.7 Permitted unprotected areas in small residential buildings