Section 13: Resisting fire spread from one building to another Methods for calculating acceptable unprotected area
Methods for calculating acceptable unprotected area
13.17
Two simple methods are given for calculating the acceptable amount of unprotected area in an external wall that is a minimum of 1000mm from any point on the relevant boundary. More precise methods are described in BRE report BR 187 and may be used instead. When using BR 187 the following radiation intensity at each unprotected area should be assumed.
Method 1
13.18
This method applies to small buildings intended to be used for ‘residential (other)’ purposes.
13.19
The building should not exceed three storeys in height (excluding basements) or 24m in length. Each side of the building should meet the limits stated in Diagram 13.7. Any small unprotected areas falling within the limits shown in Diagram 13.5 can be ignored.
Diagram 13.7 Permitted unprotected areas in small residential buildings

Method 2
13.20
This method may be used for buildings or compartments intended for any use and for which method 1 is not appropriate.
13.21
Except for an open-sided car park in purpose group 7(b) (see paragraph 11.2), the building should not exceed 10m in height. Each side of the building should meet the limits in Table 13.1. Areas falling within the limits in Diagram 13.5 can be ignored.
Table 13.1 Permitted unprotected areas in small buildings or compartments
| Minimum distance between side of building and relevant boundary (m) | Maximum total percentage of unprotected area (%) (3) | |
|---|---|---|
| Purpose groups | ||
Residential, office, assembly and recreation (1) | Shop and commercial, industrial, storage and other non-residential (2) | |
| Not applicable | 1 | 4 |
| 1 | 2 | 8 |
| 2.5 | 5 | 20 |
| 5 | 10 | 40 |
| 7.5 | 15 | 60 |
| 10 | 20 | 80 |
| 12.5 | 25 | 100 |
NOTES:
Sprinkler systems
13.22
If a building is fitted throughout with a sprinkler system in accordance with Appendix E, either of the following is permitted.
Atrium buildings
13.23
If a building contains one or more atria, the recommendations in clause B8 of BS 9999 should be followed.