Escape route design Number of escape routes and exits

Number of escape routes and exits

2.3

The number of escape routes and exits that should be provided depends on both of the following.

a. The number of occupants in the room, tier or storey.
b. The limits on travel distance to the nearest exit given in Table 2.1 (which apply only to the nearest exit; other exits may be further away).

2.4

In multi-storey buildings, if more than one stair is needed for vertical escape, every part of each storey should have access to more than one stair. An area may be in a dead end provided the alternative stair is accessible.

2.5

In mixed use buildings, separate means of escape should be provided from any storeys or parts of storeys used for the ‘residential’ or ‘assembly and recreation’ purpose groups (purpose groups 1, 2 and 5).