Escape route design Protected corridors

Protected corridors

2.24

A corridor serving as part of the means of escape in any of the following circumstances should be a protected corridor.

a. Every corridor that serves bedrooms.
b. Every dead end corridor (excluding recesses and extensions a maximum of 2m deep, as shown in Diagrams 2.7 and 2.8).
c. Any corridor shared by two or more occupancies (paragraph 2.17).

Diagram 2.7 Recesses off corridors

Diagram 2.7 Recesses off corridors. Wording on the drawing: See para 2.24; 2m max. 2m max.; 2m max.; Corridor
Diagram 2.7 Recesses off corridors

Diagram 2.8 Extension of corridor beyond a protected stairway

Diagram 2.8 Extension of corridor beyond a protected stairway. Wording on the drawing: See para 2.24; 2m max.; 2m max.; Protected stairway; Protected; stairway; Example 1 Example 2
Diagram 2.8 Extension of corridor beyond a protected stairway