Thatch and wood shingles Table 14.2 Class D-s3, d2 plastic rooflights: limitations on use and boundary distance

Table 14.2 Class D-s3, d2 plastic rooflights: limitations on use and boundary distance

Minimum classification on lower surface(1) Space that rooflight can serveMinimum distance from any point on relevant boundary to rooflight with an external designation(2) of:
EROOF(t4) or DROOF(t4)FROOF(t4)
Class D-s3, d2
a. Balcony, verandah, carport, covered way or loading bay that has at least one longer side wholly or permanently open
b. Detached swimming pool
c. Conservatory, garage or outbuilding, with a maximum floor area of 40m2
6m20m
d. Circulation space(3) (except a protected stairway)
e. Room(3)
6m(4) 20m(4)

NOTES:

None of the above designations are suitable for protected stairways. Polycarbonate and uPVC rooflights that achieve a class C-s3, d2 rating by test (see paragraph 14.7) may be regarded as having a BROOF(t4) classification. Where Diagram 8.2a or 8.2b applies, rooflights should be a minimum of 1500m from the compartment wall. If double-skinned or laminate products have upper and lower surfaces of different materials, the greater distance applies.

1. See also the guidance to requirement B2 in Section 6.
2. The designation of external roof surfaces is explained in Appendix B.
3. Single-skinned rooflight only, in the case of non-thermoplastic material.
4. The rooflight should also meet the provisions of Diagram 14.1.