5.27
Where cladding is supported by timber components or is on the façade of a timber framed building, the space between the cladding and the building should be ventilated to ensure rapid drying of any water that penetrates the cladding.
113 BRE Report BR 262 Thermal insulation: avoiding risks, 2002.
114 BRE Report 352 BRE Building elements: Walls, windows and doors, 2002.
115 BRE Report BR 292 Cracking in buildings, 1995.
116 BS 5628-3:2001 Code of practice for use of masonry. Materials and components, design and workmanship.
117 BS 8000-6:1990 Workmanship on building sites. Code of practice for slating and tiling of roofs and claddings.