Section 4: Floors Suspended timber ground floors (moisture from the ground)

Suspended timber ground floors (moisture from the ground)

4.13

Any suspended timber floor next to the ground will meet the requirement if:

a. the ground is covered so as to resist moisture and prevent plant growth; and
b. there is a ventilated air space between the ground covering and the timber; and
c. there are damp-proof courses between the timber and any material which can carry moisture from the ground.

86 BS 1282:1999 Wood preservatives. Guidance on choice, use and application.

87 BS CP 102:1973 Protection of buildings against water from the ground.

88 BS 8102:1990 Code of practice for protection of structures against water from the ground.

Technical solution

4.14

Unless it is covered with a floor finish which is highly vapour resistant (in which case see the Alternative approach in paragraph 4.16), a suspended timber floor next to the ground may be built as follows (Diagram 5):

a. Ground covering either:
i. unreinforced concrete at least 100mm thick to mix ST 1 in BS 850089. The concrete should be laid on a compacted hardcore bed of clean, broken brick or any other inert material free from materials including water-soluble sulphates in quantities which could damage the concrete; or
ii. concrete, composed as described above, or inert fine aggregate, in either case at least 50mm thick laid on at least 300µm (1200 gauge) polyethylene sheet with sealed joints, and itself laid on a bed of material which will not damage the sheet.

To prevent water collecting on the ground covering, either the top should be entirely above the highest level of the adjoining ground or, on sloping sites, consideration should be given to installing drainage on the outside of the up-slope side of the building (see Diagram 6).

b. Ventilated air space measuring at least 75mm from the ground covering to the underside of any wall-plates and at least 150mm to the underside of the suspended timber floor (or insulation if provided). Two opposing external walls should have ventilation openings placed so that the ventilating air will have a free path between opposite sides and to all parts. The openings should be not less than either 1,500mm2/m run of external wall or 500mm2/m2 of floor area, whichever gives the greater opening area. Any pipes needed to carry ventilating air should have a diameter of at least 100mm. Ventilation openings should incorporate suitable grilles which prevent the entry of vermin to the sub-floor but do not resist the air flow unduly. If floor levels need to be nearer to the ground to provide level access sub-floor ventilation can be provided through offset (periscope) ventilators.

89 BS 8500-1:2002 Concrete. Complementary British Standard to BS EN 206-1 Method of specifying and guidance for the specifier.

c. Damp-proof courses of impervious sheet material, engineering brick or slates in cement mortar or other material which will prevent the passage of moisture. Guidance for choice of materials is given in BS 5628:Part 3:200190.
d. In shrinkable clay soils, the depth of the air space may need to be increased to allow for heave.

Diagram 5 Suspended timber floor – construction (see paragraph 4.14(a) (i))

Diagram 5 Suspended timber floor – construction (see paragraph 4.14(a) (i)).
Diagram 5 Suspended timber floor – construction (see paragraph 4.14(a) (i))

Diagram 6 Suspended floor – preventing water collection (see paragraph 4.14(a))

Diagram 6 Suspended floor – preventing water collection (see paragraph 4.14(a)).
Diagram 6 Suspended floor – preventing water collection (see paragraph 4.14(a))

4.15

In areas such as kitchens, utility rooms and bathrooms where water may be spilled, any board used as a flooring, irrespective of the storey, should be moisture resistant. In the case of chipboard it should be of one of the grades with improved moisture resistance specified in BS 7331:199091 or BS EN 312 Part 5:199792. It should be laid, fixed and jointed in the manner recommended by the manufacturer. To demonstrate compliance the identification marks should be facing upwards. Any softwood boarding should be at least 20mm thick and from a durable species93 or treated with a suitable preservative.

Alternative approach

4.16

The requirement can also be met (see paragraph 4.14 above) by following the relevant recommendations of Clause 11 of BS CP 102:197394.