Buildings containing one or more atria Diagram 8.1 Compartment floors: illustration of guidance in paragraph 8.11

Diagram 8.1 Compartment floors: illustration of guidance in paragraph 8.11

Diagram 8.1 Compartment floors: illustration of guidance in paragraph 8.11. Wording on the drawing: See para 8.11; b. Compartmentation in buildings over 30m see paragraph 8.11b Compartment floor(s) or wall(s); a. Example of compartmentation in an unsprinklered assembly and recreation, shop, or commercial building see paragraph 8.11a; > 30m; Storey not exceeding; 2000m²; Storey not exceeding; Roof; 2000m²; 30m max.; Storey exceeding 2000m² divided by compartment wall; Compartment; wall; Storey exceeding 2000m² divided by compartment wall; Compartment; wall; None of the floors in this case would need to be compartment floors, but the two storeys exceeding 2000m² would need to be divided into compartments not more than 2000m² by compartment walls.; In a building with a top storey over 30m in height all storeys should be separated by compartment floors. For advice on the special conditions in atrium buildings see Annex B of BS 9999.; The compartment walls in example (a) do not need to be in one vertical plane.; d. Deep basement see paragraph 8.11d; c. Shallow basement see paragraph 8.11c; > 10m; 10m max.; Only the floor of the ground storey need be a compartment floor if the lower basement is at a depth of not more than 10m.; All basement storeys to be separated by compartment floors if any storey is at a depth of more than 10m.