Buildings containing one or more atria Table 8.1 Maximum dimensions of building or compartment (non-residential buildings)
Table 8.1 Maximum dimensions of building or compartment (non-residential buildings)
| Purpose group of building or part | Height of floor of top storey above ground level (m) | Maximum floor area of any one storey in the building or any one storey in a compartment (m2) | ||
|---|---|---|---|---|
| Single storey buildings | Multi-storey buildings | |||
| Office | No limit(1) | No limit | No limit | |
| Assembly and recreation, shop and commercial: | ||||
a. Shops – without sprinkler system | No limit(1) | 2000 | 2000 | |
| Shops – with sprinkler system(2) | No limit | No limit | 4000 | |
b. Elsewhere – without sprinkler system | No limit(1) | No limit | 2000 | |
| Elsewhere – with sprinkler system(2) | No limit | No limit | 4000 | |
| Industrial(3) | ||||
| Without sprinkler system(1) | Not more than 18 | No limit | 7000 | |
| More than 18 | N/A | 2000(4) | ||
| With sprinkler system(2) | Not more than 18 | No limit | 14,000 | |
| More than 18 | N/A | 4000(4) | ||
| Height of floor of top storey above ground level (m) | Maximum floor area (m2) | Maximum height (m)(5) | Maximum compartment volume (m3) | |
| Single storey buildings | Multi-storey buildings | |||
| Storage(3) and other non-residential: | ||||
a. Car park for light vehicles | No limit | No limit | No limit | No limit |
b. Any other building or part: | ||||
| Without sprinkler system(1) | Not more than 18 | 20,000 | 18 | 20,000 |
| More than 18 | N/A | N/A | 4000(4) | |
| With sprinkler system(2) | Not more than 18 | No limit | No limit | 40,000 |
| More than 18 | 8000(4) | |||
NOTES:
This table recommends that where the maximum size limitations placed on a building without a sprinkler system are exceeded, a sprinkler system in accordance with Appendix E should be provided.
1. See Appendix B, Table B2 for sprinkler system height requirements.
2. ‘With sprinkler system’ means that the building is fitted throughout with an automatic sprinkler system in accordance with Appendix E.
3. In certain industrial and storage uses that are subject to other legislation, for example the storage of LPG and certain chemicals, additional limitations on floor area and/or additional sprinkler provisions might apply.
4. This reduced limit applies only to storeys that are a minimum of 18m above ground level. Below this height the higher limit applies.
5. Compartment height is measured from finished floor level to the underside of the roof or ceiling.